HK6-DZ47LED RCBO DISTRIBUTION BOX 10A~60A

Payment Note: Check out with PayPal - Credit cards accepted (no PayPal account required) PRODUCT INTRODUCTION The HK6‑DZ47LED IP65 Waterproof, Dustproof and Surge-Protected RCBO Distribution Box is a factory-assembled, high-performance power distribution solution designed to operate reliably in harsh environments. By integrating a heavy-duty DZ47LED-2LNE Residual Current Circuit Breaker with Overcurrent Protection...
Current
-
+
$30.00

DIHOOL

499 In Stock

Payment Note: Check out with PayPal - Credit cards accepted (no PayPal account required)

PRODUCT INTRODUCTION

The HK6‑DZ47LED IP65 Waterproof, Dustproof and Surge-Protected RCBO Distribution Box is a factory-assembled, high-performance power distribution solution designed to operate reliably in harsh environments. By integrating a heavy-duty DZ47LED-2LNE Residual Current Circuit Breaker with Overcurrent Protection (RCBO) within a rugged, weather-resistant HK6 enclosure, this unit delivers comprehensive, all-in-one safety defense against earth leakage, overload, short circuits, lightning surges, over-voltage, and under-voltage.

Electrical Parameters

RCBO Core Parameters
Rated Current 10A, 15A, 20A, 25A, 30A, 40A, 50A, 60A
Poles 3P(L1+L2+N) + PE (Dual Live Wire)
Rated Voltage (Ue) 120/240V AC (Split-phase)
Rated Insulation Voltage (Ui) 500V
Rated Breaking Capacity(lcn) 6kA
Rated Impulse Withstand Voltage (Uimp) 4kV (1.2/50μs)
Dielectric Test Voltage 2kV (Ind. Freq. for 1 min)
Residual Current Type Type A
Rated Residual Operating Current (IΔn) 30mA(default), customizable to 15 mA, 50mA, 100mA, or 300 mA
Tripping Characteristic C-Curve (5-10In)
Electrical Life 4,000 cycles
Mechanical Life 10,000 cycles
Mounting 35mm DIN Rail
Operating Ambient Temperature -5℃ to +40℃
Terminal Type Screw Terminal (Phillips/Slotted Combo)
Terminal Capacity 1.5 - 25 mm² (16 - 4 AWG)
Tightening Torque 2.5 N·m (22 lb-in)
Pollution Degree 2 (Standard)
Maximum Altitude ≤ 2000m
Certification IEC61009-2-2
Frequency 50/60Hz
Surge Protection Parameters
Max Discharge Current (8/20μs) 20 kA
Nominal Discharge Current (8/20μs) 10 kA
Response Time < 25 ns
The ground terminal links the stranded copper conductors 6mm²
HK6 Enclosure Parameters
Protection Rating IP65 (IEC 60529)
Material Flame-retardant ABS housing (UL94 V-0) + Dark-tinted semi-transparent UV-resistant PC cover
External Dimensions (W×D×H) 165 × 100 × 200 mm
Mounting Wall-mount with 4-point fixing (40mm pitch holes)
Door 180° swing-open with silicone gasket seal
Internal Rail 35mm standard DIN rail, 6-module capacity
Operating Temperature Range -25°C to +60°C
Cable Entry Bottom reserved 1‑inch opening, compatible with 1‑inch Liquid Tight Connector; equipped with 1‑inch to 3/4‑inch reducing gasket included
RCD Types
Type AC
General Purpose Use
RCD can detect and respond to AC sinusoidal wave only.
Type A
Equipment incorporating electronic components
RCD can detect and respond as for type AC,
Plus pulsating DC conponents.

Description Of RCBO Appearance

HK6 Enclosure Appearance

The Main Difference Between Type A And Type AC

Form Residual Current and Current Waveform that can trip Trip Current Range
Type AC AC Residual Current 0.5I△-I△n
Type A AC Residual Current 0.5I△-I△n
Pulsating DC Residual Current 0.35~1.4I△n (or 2I△n)(Current lag Angle 0°)
0.25~1.4I△n (or 2I△n)(Current lag Angle 90°)
0.11~1.4I△n (or 2I△n)(Current lag Angle 135°)
Current Stacking 6mA Pulsating Direct Current 1.4I△n (or 2I△n) + 6mA

Installation Instructions

Dimensions And Wring Instructions