DZ47LED-2LNE Residual Current Circuit Breaker 10A~60A

Payment Note: Check out with PayPal - Credit cards accepted (no PayPal account required) PRODUCT INTRODUCTION The DZ47LED-2LNE is a high-performance Type A Residual Current Circuit Breaker with Overcurrent Protection, integrating comprehensive electrical safety functions into a single, compact device. Designed specifically for 120/240V split-phase (dual live wire) power systems, it features...
Current
-
+
$20.00

DIHOOL

499 In Stock

Payment Note: Check out with PayPal - Credit cards accepted (no PayPal account required)

PRODUCT INTRODUCTION

The DZ47LED-2LNE is a high-performance Type A Residual Current Circuit Breaker with Overcurrent Protection, integrating comprehensive electrical safety functions into a single, compact device. Designed specifically for 120/240V split-phase (dual live wire) power systems, it features a 2P+N+PE wiring structure. This design ensures the simultaneous disconnection of both live conductors (L1, L2) and the neutral conductor (N) during a fault, while a dedicated protective earth terminal (PE) provides a reliable grounding path for enhanced safety.
This multi-functional device offers complete protection against earth leakage, overload, and short-circuit faults. It is engineered for regions utilizing low-voltage split-phase systems, such as North America, Japan, and Taiwan China. A key feature is its support for both Type A and Type AC residual current detection, providing flexibility for applications with different types of electrical loads. With a rated current range of 10A to 60A, the breaker delivers reliable, standardized protection for terminal circuits in residential, commercial, and light industrial applications.

Electrical Parameters

Rated Current 10A, 15A, 20A, 25A, 30A, 40A, 50A, 60A
Poles 3P(L1+L2+N) + PE (Dual Live Wire)
Rated Voltage (Ue) 120/240V AC (Split-phase)
Rated Insulation Voltage (Ui) 500V
Rated Breaking Capacity 6kA
Rated Impulse Withstand Voltage (Uimp) 4kV (1.2/50μs)
Dielectric Test Voltage 2kV (Ind. Freq. for 1 min)
Residual Current Type Type A
Rated Residual Operating Current (IΔn) 30mA(default), customizable to 15 mA, 50mA, 100mA, or 300 mA
Tripping Characteristic C-Curve (5-10In)
Electrical Life 4,000 cycles
Mechanical Life 10,000 cycles
Mounting 35mm DIN Rail
Operating Ambient Temperature -5℃ to +40℃
Terminal Type Screw Terminal (Phillips/Slotted Combo)
Terminal Capacity 1.5 - 25 mm² (16 - 4 AWG)
Tightening Torque 2.5 N·m (22 lb-in)
Pollution Degree 2 (Standard)
Maximum Altitude ≤ 2000m
Certification IEC61009-2-2
Frequency 50/60Hz
Surge Protection Parameters
Max Discharge Current (8/20μs) 20 kA
Nominal Discharge Current (8/20μs) 10 kA
Response Time < 25 ns
The ground terminal links the stranded copper conductors 6mm²
RCD Types
Type AC
General Purpose Use
RCD can detect and respond to AC sinusoidal wave only.
Type A
Equipment incorporating electronic components
RCD can detect and respond as for type AC,
Plus pulsating DC conponents.

Description Of Appearance

The Main Difference Between Type A And Type AC

Form Residual Current and Current Waveform that can trip Trip Current Range
Type AC AC Residual Current 0.5I△-I△n
Type A AC Residual Current 0.5I△-I△n
Pulsating DC Residual Current 0.35~1.4I△n (or 2I△n)(Current lag Angle 0°)
0.25~1.4I△n (or 2I△n)(Current lag Angle 90°)
0.11~1.4I△n (or 2I△n)(Current lag Angle 135°)
Current Stacking 6mA Pulsating Direct Current 1.4I△n (or 2I△n) + 6mA