Category

IPS-S2 Controller

PRODUCT DESCRIPTION IPS-S2 motor controller that integrates infrared/radio frequency/WIFI/ button control, mainly used to control electric linear actuators. The controller is compatible with voltage of DC10V~30V, maximum current of 10 A. The positive and negative poles need to be wired according to the wiring diagram. If the positive and negative...
Model
-
+
$5.00

DIHOOL

72 In Stock

PRODUCT DESCRIPTION

IPS-S2 motor controller that integrates infrared/radio frequency/WIFI/ button control, mainly used to control electric linear actuators. The controller is compatible with voltage of DC10V~30V, maximum current of 10 A. The positive and negative poles need to be wired according to the wiring diagram. If the positive and negative connections are not correct, it will not burn the controller. For example, 60W Iinear actuator, please choose 60-90W power adapter/switch power supply. If use smaller power, the motor will not working. The controller can be used to control various specifications of electric linear actuators. WIFI module can be controlled through the "eWelink" APP, and only supports 2.4G WIFI. There are 6 buttons F1, F2, F3, ▲, ▼, on the controller for adjusting various functions. Please refer to the following for detailed instructions. The ▲ / ▼ button controls the forward and backward movement of the motor; The button learns WIFI.

TECHNICAL PARAMETERS

Model IPS-S2 DC Connector 5.5*2.1MM
Input Voltage DC 10V-30V Receiving Frequency RF433MHz/2.4GHz
Output Voltage 20-93% Input Voltage Adjustable WIFI Protocol IEE802.11 b/g/n
Max Current 10A Remote Control Battery 23A 12V
Current Monitoring Accuracy ±0.3A Working Temperature -20℃~+70℃
Power Consumption <3W Working Humidity 10%~90%RH (NO CONDENSATION)
Input Signal Type NPN    

 

The Main Functions

1. Controller button control: Press the ▲ button to up and the ▼ button to down. If not correct, please switch to connecting the motor cable.
2. RF433 remote control: It can be adapted to the RF433 remote control (with three buttons for forward, pause, and backward), and one controller can be equipped with 8 remote controls. (Provide 1 remote control by default)
3. Infrared remote control: Each infrared remote control can be controlled
4. Manual controller: optional with 2.5 meter manual controller for control (press move)/optional with foot controller for control (press move)
5. WIFI control: You can use the L button to connect 2.4G WIFI for lifting control. (First time adapting to WIFI, please approach the router)
6. Button control: Can be controlled using industrial button switches
7. Current limiting control: Set the maximum current of the controller through the F1 button. When the motor exceeds the current, the motor will stop

FUNCTION F1: MOTOR PROTECTION SETTINGS
Press and hold the F1 key for 3 seconds to enter the F1 sub-function settings, click F1 to switch in the sub-functions, and hold the F1 key for 3 seconds to exit the setting (press "▲" to increase / "▼" to adjust the value)
Code/Subfunction Name Subfunction Parameter Description Value Default Value Unit
A Overcurrent Protection Upward overcurrent protection A010~A100 A04.0 (Amp)
b Downward overcurrent protection b010~b100 b01.0 (Amp)
C Operation Mode C-1 Jogging, C-0: Self-holding, U-1 time-delay C-1~C999 C000 (Seconds)
d Stall Detection Protection Downward Stall Detection Protection D0.0~D9.9 D0.6 (Amp)
E Upward Stall Detection Protection E0.0~E9.9 E0.0 (Amp)
F Stall Reverse Time Obstruction rebound duration F000~F999 F001 (Seconds)
G Stall Protection Time-delay Intervention Set the time for delayed intervention of stall protection G0.0~G3.0 G0.30 (Seconds)
H Percentage of QV Voltage Regulation Range Downward voltage regulation range (20%-93%) H000~H093 H093 (%)
J Upward voltage regulation range (20%-93%) J000~J093 J093 (%)
L Display Brightness Adjustment Screen brightness ranges from 1 (dim) to 8 (bright) L001~L008 L005  
P Operation Mode Of Wired Controller Foot switch / wired controller (0: Jogging, 1: Self-holding) P 0 / P 1 P 0  
t Screen Off Time The default time is 5 minutes t000~t999 t005 (Minutes)
Lo Soft Stop 0: Turn Off, 1: Turn On Lo 0 / Lo 1 Lo 0  
FUNCTION F2: SIGNAL OPERATION SETTING
Press and hold the F2 key for 3 seconds to enter the F2 sub-function settings, click F2 to switch in the sub-functions, and hold the F2 key for 3 seconds to exit the setting (press "▲" to increase / "▼" to adjust the value)
Code/Subfunction Name Subfunction Parameter Description Value (Unit)
A Up Working Time Motor Up Working Time A000~A999 (Seconds)
b Pause Time Motor Pause Time b000~b999 (Seconds)
C Down Working Time Motor Down Working Time C000~C999 (Seconds)
d Operation Mode
0: Motor Working 1: Motor Not Working
0: Signal Present, stop. Signal disappear, execute actions A,b,c
1: Signal Present, stop after executing action A. Signal disappear, execute actions b and c
d000~d001 /
FUNCTION F3: AUTOMATIC OPERATION SETTING
Press and hold the F3 key for 3 seconds to enter the F3 sub-function settings, click F3 to switch in the sub-functions, and hold the F3 key for 3 seconds to exit the setting (press "▲" to increase / "▼" to adjust the value)
Code/Subfunction Name Subfunction Parameter Description Value (Unit)
A Up Working Time Motor Up Working Time A000~A999 (Seconds)
b Pause Time Motor Pause Time b000~b999 (Seconds)
C Down Working Time Motor Down Working Time C000~C999 (Seconds)
d Pause Time Motor Pause Time d000~d999 (Seconds)
E Number Of Cycles The Number Of Cycles Of The Motor E000~E999 (frequency)
F Cycle Operation Mode: 0-Close, 1-Start 0: Close Cycle Operation, 1: Start Cycle Operation Press the "▲" / "▼" To start, press again to close F000/F001 /

DIMENSIONS AND WIRING INSTRUCTION